立方 LIMS 使用教程，第 4 集

2
00:00:03,760 --> 00:00:06,320
样品接收、流转与偏离处置

3
00:00:08,350 --> 00:00:10,270
样品从现场回到实验室

4
00:00:10,270 --> 00:00:16,030
要经过交出、接收、入库、发放检测、归还、留样和处置

5
00:00:16,030 --> 00:00:20,150
这一集按顺序走一遍，再讲偏离和处置的申请与审批

6
00:00:20,150 --> 00:00:21,390
以及拒收样品

7
00:00:22,910 --> 00:00:24,950
所有流转有一个共同点

8
00:00:24,950 --> 00:00:28,590
每一步都由经手人用自己的账号点本人确认

9
00:00:28,590 --> 00:00:31,910
时间由系统记录，不能补填，也不能替别人点

10
00:00:33,350 --> 00:00:36,830
采样员回到实验室，登录后首页的我的待办里

11
00:00:36,830 --> 00:00:40,430
会列出已经采集、还没交出的样品，点它打开

12
00:00:41,950 --> 00:00:46,510
样品页上方是样品信息，下方是流转记录

13
00:00:46,510 --> 00:00:50,110
样品编号是现场登记时系统生成的

14
00:00:50,110 --> 00:00:51,350
点右上角的交出

15
00:00:52,870 --> 00:00:56,390
选择交给哪位样品管理员，写上样品状况

16
00:00:56,390 --> 00:01:00,270
再选封口是否完好，这一项必须明确选择

17
00:01:00,270 --> 00:01:01,590
最后点本人确认

18
00:01:03,030 --> 00:01:05,470
流转记录里多了一条交出

19
00:01:05,470 --> 00:01:10,140
谁交给谁、什么时间、什么状况，一目了然

20
00:01:10,140 --> 00:01:12,020
样品状态变成交接中

21
00:01:13,500 --> 00:01:15,180
样品管理员登录后

22
00:01:15,180 --> 00:01:20,540
首页的四个数字是待接收、已接收待入库、在库和留样

23
00:01:20,540 --> 00:01:23,700
我的待办里列出送给自己、等着接收的样品

24
00:01:25,420 --> 00:01:29,940
也可以点菜单里的样品，按状态筛选，比如选交接中

25
00:01:29,940 --> 00:01:34,820
还可以按样品编号、名称或批号搜索

26
00:01:34,820 --> 00:01:38,100
右上角的登记来样，用于客户送上门的样品

27
00:01:38,100 --> 00:01:39,580
见第 13 集

28
00:01:39,580 --> 00:01:41,500
点样品编号就进入样品页

29
00:01:42,980 --> 00:01:44,340
交接中的样品

30
00:01:44,340 --> 00:01:47,620
只有被指定的接收人本人才能接收或拒收

31
00:01:49,100 --> 00:01:51,820
点接收，先做接收检查

32
00:01:51,820 --> 00:01:56,420
箱温、封签、保存剂、是否在保存时限内

33
00:01:56,420 --> 00:01:58,980
写进样品状况，点本人确认

34
00:02:00,460 --> 00:02:05,060
接着点入库，填写库位，比如样品冷藏柜 A-03

35
00:02:05,060 --> 00:02:07,620
点本人确认，样品就进了样品库

36
00:02:09,100 --> 00:02:13,260
检测员要做分析时，样品管理员点发放分析

37
00:02:13,260 --> 00:02:16,600
选择领用的检测员，点本人确认

38
00:02:16,600 --> 00:02:18,440
流转里记下发给了谁

39
00:02:19,920 --> 00:02:23,760
检测员用完样品，打开同一个样品点归还

40
00:02:23,760 --> 00:02:28,270
分析已经做完的，勾上分析已完成；还要再做的不勾

41
00:02:28,270 --> 00:02:29,910
样品回库后还能再发放

42
00:02:31,390 --> 00:02:34,630
分析完成的样品，样品管理员可以点留样

43
00:02:36,110 --> 00:02:39,670
填写留样的库位，比如留样柜 R-02

44
00:02:39,670 --> 00:02:42,150
再填留样期限，点本人确认

45
00:02:43,630 --> 00:02:46,470
留样期限显示在样品信息下方

46
00:02:46,470 --> 00:02:50,150
期满前要处置，比如样品变质或客户取回

47
00:02:50,150 --> 00:02:53,390
须先申请提前处置，经批准后才能处置

48
00:02:54,870 --> 00:02:56,430
不需要留样的样品

49
00:02:56,430 --> 00:02:59,950
处置前也要先申请、由质量负责人批准

50
00:02:59,950 --> 00:03:02,150
打开偏离与处置，点申请

51
00:03:03,670 --> 00:03:07,510
类型选样品处置，按样品编号选中样品

52
00:03:07,510 --> 00:03:10,070
写明处置原因，点提交

53
00:03:10,070 --> 00:03:11,990
处置类的申请不写入报告

54
00:03:13,470 --> 00:03:16,700
同一个页面也用来申请偏离

55
00:03:16,700 --> 00:03:20,260
比如样品送达时已经超过方法规定的保存时限

56
00:03:20,260 --> 00:03:23,060
类型选超保存时限，写明原因

57
00:03:23,060 --> 00:03:24,980
再写一句写入报告的说明

58
00:03:26,460 --> 00:03:30,060
批准后，这句说明会自动写进报告的偏离一节

59
00:03:30,060 --> 00:03:31,780
不用编制人再手抄

60
00:03:31,780 --> 00:03:34,460
提交后，两条申请都显示待审批

61
00:03:35,900 --> 00:03:39,820
质量负责人打开偏离与处置，逐条看原因和报告说明

62
00:03:39,820 --> 00:03:43,290
点批准或驳回；驳回要写原因

63
00:03:43,290 --> 00:03:45,050
申请人不能批准自己的申请

64
00:03:46,570 --> 00:03:50,490
批准前系统会请你再确认一次，点同意

65
00:03:50,490 --> 00:03:52,010
申请就显示已批准

66
00:03:53,450 --> 00:03:57,880
处置申请批准后，样品管理员回到样品页点处置

67
00:03:57,880 --> 00:04:01,640
在已批准的处置申请里选中这一条，点本人确认

68
00:04:03,320 --> 00:04:07,160
样品状态变为已处置，整条流转链完整保留

69
00:04:08,880 --> 00:04:13,840
如果接收检查发现问题，比如样品瓶破裂、水样不够

70
00:04:13,840 --> 00:04:17,600
就点拒收，写明拒收原因，点本人确认

71
00:04:19,280 --> 00:04:23,240
样品状态变为已拒收，对应的检测任务会自动作废

72
00:04:23,240 --> 00:04:25,560
需要补采的，请另行安排采样

73
00:04:27,210 --> 00:04:28,970
这一集就到这里

74
00:04:28,970 --> 00:04:31,770
下一集进入实验室分析

75
00:04:31,770 --> 00:04:36,650
站长分派检测任务，检测员在原始记录里录入读数

76
00:04:36,650 --> 00:04:39,010
系统当场计算结果并判定质控